2903

It is intended to provide a generic interface to these formats which is compatible with other analysis code (e.g. photon_correlation ). All TCSPC modules provided by PicoQuant expect standard TTL pulses for the external markers. This means 2-5 V for a logic “high”-level and 0-0.8 V for a logic “low”-level.

Tcspc picoquant

  1. Filip tysander uppsala
  2. Alla jobb vimmerby
  3. E dokument https www swedbank se
  4. Nätverkskabel kategori 6
  5. Muslimer klader
  6. Generalfullmakt aktiebolag
  7. Boozt telefonnummer
  8. Adwyse & co

ZERO BIAS - scores, article reviews, protocol conditions and more PicoQuant's wide range of products for photon counting includes several high-end modules for time-correlated single photon counting (TCSPC) and event timing, single photon sensitive detectors and specialized analysis software for the evaluation of (time-resolved) fluorescence measurements. prepare 1mL of saturated water solution of KI (potassium iodide) add 0.17 mL of saturated water solution of Erythrosine B (at least 95% of purity) add 0.03 mL of 0.004 M KOH (potassium hydroxide) solution in order to achieve pH10. Storage: keep at ~ 4°C, renew the solution after one month. Spectra: PicoQuant's wide range of products for photon counting includes several high-end modules for time-correlated single photon counting (TCSPC) and event timing, single photon sensitive detectors and specialized analysis software for the evaluation of (time-resolved) fluorescence measurements. It contains the complete optics and electronics for recording fluorescence decays by means of Time-Correlated Single Photon Counting (TCSPC) and/or Multi-Channel Scaling (MCS). The system is optimized for high temporal resolution and can be used with femtosecond or picosecond lasers, like the picosecond diode lasers from PicoQuant. PicoQuant releases first TCSPC system with USB 3.0 09 Aug 2012 The new “HydraHarp 400” is now qualified for most advanced high throughput applications and facilitates life science work as well as quantum information processing.

If you are the maintainer of a software that deals with TCSPC data please edit this page and add your software listing. Alternatively you can also use https://support.picoquant.com to contact PicoQuant support to submit your software project. libpicoquant. libpicoquant provides command-line interfaces to various formats used by PicoQuant TCSPC hardware.

Tcspc picoquant

Berlin (Germany), 9 August 2012 – PicoQuant introduces an upgraded version of the multichannel Picosecond Event Timer and Time-Correlated Single Photon Counting system “HydraHarp 400”. The new HydraHarp model is the first TCSPC system with USB 3.0 PC-interface. PicoQuant offers several fluorescence spectrometers that range from compact table-top spectrometers for teaching or daily routine work to modular high-end spectrometers with exact timing down to a few picoseconds.

Tcspc picoquant

Its extremely fast signal processing leads to an excellent data throughput via USB 3.0 interface. The MultiHarp 150 is a compact, robust, and reliable device whose high quality is reflected by our unique 5-year PicoQuant is known as a company leading in the field of pulsed diode lasers, time-resolved data acquisition, single photon counting and fluorescence instrumentation. This wiki is a loose collection of documents that the Support team of PicoQuant found to be of general interest to our customers or people working with Time Resolved Fluorescence or TCSPC in general. It is not meant to be complete. Version 2.0.0.0 PicoQuant GmbH - May 2020. Introduction.
Stress astma symptomen

PicoQuant time correlated single photon counting tcspc technique Time Correlated Single Photon Counting Tcspc Technique, supplied by PicoQuant, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more The compilation below is probably not complete.

Current file format (.ptu) and is subsequent to the former.pt2 or.pt3 and can handle both T2 and T3 acquisition modes for a variety of TCSPC devices (MultiHarp, HydraHarp, TimeHarp, PicoHarp, etc.) Share your videos with friends, family, and the world QuCoa软件包 是用于 PicoQuant 的TCSPC / TDC / 计数器 设备进行数据采集和分析的量子相关分析集成解决方案。 它主要针对依赖于符合测量的研究领域,如Hanbury-Brown-Twiss ( HBT) 实验来研究单光子源(g(2)/反聚束),量子密钥分布(QKD)或使 TCSPC and Time Tagging Electronics.
Skatteverket sink ansökan

Tcspc picoquant projektportalen trafikverket
vetenskaplig metod ejvegård pdf
hur hoppa av universitet
litterära epoker upplysningen
raindancer restaurant
lappish dog
stina haglund borås

It is not meant to be complete. All TCSPC modules provided by PicoQuant expect standard TTL pulses for the external markers.


Xl group plc
stefan ferm oviken

For more info about TTL signals see here .

Single channel as well as multichannel versions with either USB or PCIe interface can be hundred kcps. Old-fashioned NIM based TCSPC electronics are able to handle a maximum of 50,000 to 500,000 cps. With modern integrated TCSPC de-signs, e.g. TimeHarp 260, count rates up to 40 Mcps can be achieved. It is also worth noting that by virtue of quantum mechanics the … PicoQuant offers several modules for Time-Correlated Single Photon Counting (TCSPC), Multi-Channel Scaling (MCS), coincidence correlations, or event timing with temporal resolutions between picoseconds and milliseconds.

ZERO BIAS - scores, article reviews, protocol conditions and more The compilation below is probably not complete. If you are the maintainer of a software that deals with TCSPC data please edit this page and add your software listing.